Home › Forums › Trade Technical & Spare Parts Forums › Trade Technical Enquiries › Hotpoint’s not draining
- This topic has 14 replies, 6 voices, and was last updated 13 years, 3 months ago by
iadom.
-
AuthorPosts
-
January 4, 2013 at 4:03 pm #73351
iadom
ModeratorHad three like this in past couple of weeks. Today it was an 18 month old WDL540.
Pump and hoses all clear, set it to drain only and the pump runs for a couple of seconds then cuts out. No sign of an overload in these pumps but on all three machines I have plugged the connector into a brand new pump with exactly the same results.
I am assuming that there is a pcb fault, unless you know better. 😉
Jim.
January 4, 2013 at 4:57 pm #387184madangler1
ParticipantRe: Hotpoint’s not draining
If its the linear pressure switch model then it won’t drain with out any water in it, Otherwise check the door lock, I have seen these cause a number of really strange problems on the Arcadia electronics, possibly motor as well. The module will not pump or do anything if either motor or door lock is playing up
I had one last week doing something similar, door locked and light was on as it should be but it just would not do anything. After trying everything else tried the interlock
Not seen many on these doing it though 3 is unusual.
January 4, 2013 at 5:26 pm #387185iadom
ModeratorRe: Hotpoint’s not draining
Thanks, will look out for that next time.
Jim.
December 6, 2013 at 11:54 am #387186allan73
ParticipantRe: Hotpoint’s not draining
Did you get to the bottom of this one Iadom ?
I’ve got one of these with the same fault. Customer has removed a hair grip from the filter so I’m wondering if board damage has occurred.
AllanDecember 6, 2013 at 2:06 pm #387187timdowning
ParticipantRe: Hotpoint’s not draining
Not forgetting this thread either –
December 6, 2013 at 2:46 pm #387188allan73
ParticipantRe: Hotpoint’s not draining
Thanks Tim. I have tried to reset the pressure switch also, to no avail.
AllanDecember 6, 2013 at 3:23 pm #387189iadom
ModeratorRe: Hotpoint’s not draining
I seem to remember johnnyj posting that on some occasions he has had to rewrite the eeprom.
December 6, 2013 at 3:57 pm #387190allan73
ParticipantRe: Hotpoint’s not draining
Thanks I’ll speak to the customer.
AllanDecember 6, 2013 at 10:07 pm #387191A1engineer
ParticipantRe: Hotpoint’s not draining
guys I’ve had this a few times on the washer dryers believe it or not its a faulty dryer ntc or ntc wiring 🙂
don’t ask me why 🙂
December 6, 2013 at 10:19 pm #387192allan73
ParticipantRe: Hotpoint’s not draining
Would the NTC stop the pump from being energised ?
The machine will fill, wash and spin when emptied manually.
AllanDecember 6, 2013 at 10:33 pm #387193A1engineer
ParticipantRe: Hotpoint’s not draining
when the ntc fault occurs the pump runs for about 2 seconds then cuts off, reset and try again it will again run for 2 seconds etc
if you have a linear pressure switch or software issue then the pump wouldn’t run at all as the machine thinks its empty( even tho its not)
December 6, 2013 at 10:39 pm #387194allan73
ParticipantRe: Hotpoint’s not draining
Interesting…that’s exactly the problem, thanks A1 !
AllanJanuary 8, 2015 at 10:30 pm #387195hilly
ParticipantRe: Hotpoint’s not draining
did you sort yours allan?
ive got a indesit w/m and a hotpoint w/d with the same problem they will do the full spin but only drains for a few seconds.
the hotpoint I disconnected everything apart from interlock, pressure switch and pump and it still did the same, but no error codecheers paul
January 8, 2015 at 10:42 pm #387196allan73
ParticipantRe: Hotpoint’s not draining
My problem was dryer NTC on washer dryer Paul. Had the same problem a few times since posting.
Pump runs for a few seconds then cuts off, common fault it seems.Allan
January 8, 2015 at 11:21 pm #387197hilly
ParticipantRe: Hotpoint’s not draining
cheers allan
-
AuthorPosts
- You must be logged in to reply to this topic.