Creda TCR2 Dryer no heat Home › Forums › Trade Technical & Spare Parts Forums › Trade Technical Enquiries › Creda TCR2 Dryer no heat This topic has 5 replies, 3 voices, and was last updated 13 years, 2 months ago by robbra. Viewing 6 posts - 1 through 6 (of 6 total) Author Posts January 30, 2013 at 6:07 pm #73864 robbraParticipant Hi, Heater stats and front stat ok. At the heater joint block three live and no neutral so no heat. I suspect the timer but as not had a timer go before don’t want to jump in. Any advice welcome. Thanks Rob January 30, 2013 at 7:49 pm #389115 suedehead1Participant Re: Creda TCR2 Dryer no heat i have had to change the timer before for the same fault. January 31, 2013 at 11:13 am #389116 robbraParticipant Re: Creda TCR2 Dryer no heat Thanks, Just what I needed to know. I’ll order it. Rob February 7, 2013 at 7:16 am #389117 robbraParticipant Re: Creda TCR2 Dryer no heat Had a wiring diagram and it was a burnt out float switch. Would not have thought of this causing no heat. Thanks Jim February 7, 2013 at 7:23 am #389118 johnnyjParticipant Re: Creda TCR2 Dryer no heat Why not the circuit goes through the float switch, when the chamber is full the switch breaks and breaks the circuit to the heater. February 7, 2013 at 7:41 am #389119 robbraParticipant Re: Creda TCR2 Dryer no heat Because I wasn’t aware of that Johnny Author Posts Viewing 6 posts - 1 through 6 (of 6 total) You must be logged in to reply to this topic. Log In Username: Password: Keep me signed in Log In