Hoover vhv680c condensor dryer

Home Forums Trade Technical & Spare Parts Forums Trade Technical Enquiries Hoover vhv680c condensor dryer

Viewing 4 posts - 1 through 4 (of 4 total)
  • Author
    Posts
  • #74970
    scoobya1
    Participant

    This one is running for ten mins then just shuts down with all lights flashing. I found a previous post raising the same question, but there were no replies. Does anyone have the answer now please?

    #393453
    keithwilliams
    Participant

    Re: Hoover vhv680c condensor dryer

    well i could be wrong but ive lately had a couple of these where the wires on the door lock switch were burnt out. it could be that yours is nearly but not quite burnt through but is eventually breaking down under the heater load.

    #393454
    Muv
    Participant

    Re: Hoover vhv680c condensor dryer

    Hi


    Ive got to look at one of these machines tommorow,with the same fault as described.
    I was just wondering if the interlock is easy to get at? and are these machines the welded cabinet type, where everything is only accesible from the front…

    Thanks
    Martin

    #393455
    Muv
    Participant

    Re: Hoover vhv680c condensor dryer

    Update

    Turned out it was a very badly overheated heater assembly, so got new one on order

    Martin