Re: Hotpoint WMA32 not taking away conditioner
Seamy,
When the fabric conditioner is activated on a WMA series BOTH cold solenoids are energised together. The idea being that the convergance of flow down both channels forces the water FORWARD at that juncture towards the fabric conditioner channel on the F/L/H/Side 😀
So there are 3 possibles here for you to check, one, not enough mains pressure, two, channels blocked or restricted and finally not both solenoids are working :con: