Question for the Bosh experts

Home Forums Trade Technical & Spare Parts Forums Trade Technical Enquiries Question for the Bosh experts

Viewing 3 posts - 1 through 3 (of 3 total)
  • Author
    Posts
  • #76966
    allan73
    Participant

    Just been to a Bosh WAE24166gb/06 and found an open circuit inlet solenoid. I’ve replaced the solenoid with a universal one from my van but now the m/c overfills, and the valve is energised even when the programme is paused.
    Is this because I need to order the correct part or a board fault likely ?
    Allan.

    #400274
    Martin
    Participant

    Re: Question for the Bosh experts

    It could be the faulty valve took out the triac on the PCB. Best you take a close look at the PCB surface components. 💡

    #400275
    allan73
    Participant

    Re: Question for the Bosh experts

    Will do,thanks Martin.

Viewing 3 posts - 1 through 3 (of 3 total)