WT46W560 GB/01 Not Drying.

Viewing 5 posts - 1 through 5 (of 5 total)
  • Author
    Posts
  • #78503
    Turbo
    Participant

    Hi

    Customer complaining that sometimes the sensor dry programs leave the washing far too damp. Happens about once in 7 loads.
    Any suggestions.

    Thanks

    Graham

    #405905
    Martin
    Participant

    Re: WT46W560 GB/01 Not Drying.

    Heat pump Siemens is it? You’ve gotta hope it is an NTC problem as your best option. 🙁

    #405906
    Turbo
    Participant

    Re: WT46W560 GB/01 Not Drying.

    Correct it has the heat pump Martin.
    How does this model measure the damp in the clothes?

    #405907
    Martin
    Participant

    Re: WT46W560 GB/01 Not Drying.

    Turbo wrote:How does this model measure the damp in the clothes?

    IIRC there’s an NTC located on the capillary tube that measures the heat level from the drum air outlet.

    #405908
    Turbo
    Participant

    Re: WT46W560 GB/01 Not Drying.

    Does anyone know how you change the thermistor at the front of the dryer, do you have to take the front panel off or can you remove the right hand fan cover for access?

    Thanks
    Graham