    …open door during its drain phase.

    start it up, drains, then activates circ motor but doesn’t take water in, senses its empty so then goes back to draining. continues this then the no fill light coming on.

    weird thing is if you open door during the draining phase, it will start to fill.

    have already replaced reed switch to find no change in symptoms.

    already have pump and would have tried that but its the extra deep carcass, which means the pump is nigh on impossible to replace without full strip down, as its sitting hard on base.

    am wondering if its possible theres an issue with the door lock sensor, has anyone else had any similar issues?

    #406017
    electrofix
    Moderator

    Re: Bosch new format SBV50E10 wierdness – wont work unless y

    not sure but,
    From what i have read etc the pump is 3 phase ( therefore has 3 wires going to it) they use the current going to the pump to sense when unit is empty. if pump is getting worn and jamming it will draw more current and therefore board will not sense it is empty

    you may have to try the pump change to find out

    Dave

    #406018
    Martin
    Participant

    Re: Bosch new format SBV50E10 wierdness – wont work unless y

    electrofix wrote:not sure but,
    From what i have read etc the pump is 3 phase ( therefore has 3 wires going to it) they use the current going to the pump to sense when unit is empty.

    Spot on Dave. Below is an example of its wiring to the power board….

    #406019
    gandh1
    Participant

    Re: Bosch new format SBV50E10 wierdness – wont work unless y

    “vorsprung durch รผber technik” then

    #406020
    CARLJONESDAR
    Participant

    Re: Bosch new format SBV50E10 wierdness – wont work unless y

    I have the same problem on the same model. Did the new pump fix the problem?

    #406021
    eng14
    Participant

    Re: Bosch new format SBV50E10 wierdness – wont work unless y

    hi all had the same fault on friday,do you mean the drain pump or wash pump,richard. ๐Ÿ˜•

    #406022
    Martin
    Participant

    Re: Bosch new format SBV50E10 wierdness – wont work unless y

    The drain pump.

    #406023
    eng14
    Participant

    Re: Bosch new format SBV50E10 wierdness – wont work unless y

    ๐Ÿ˜€ thanks martin,stupid little pumps far worse than the old type,richard