Re: indesit washer dryer iwde126
Same as these AFAIK.
widl codes – light flashing from left to right are numbers 1-4
f01 light 4, motor triac
f02 light 3 motor, jammed/ tacho
f03 lights 3&4 Ntc fault
f04 light 2. pressure sw stuck on empty
f05 lights 2&4, pressure sw stuck on full
f06 lights 2&3, N/A?
f07 lights 2&3&4 heater relay or O/C element.
f08 light 1. heater relay
f09 lights 1&4 eprom/setup error
f10 lights 1&3, pressure switch not sensing
f11 lights 1&3&4, pump/draining error
f12 lights 1&2, communication error
f13 lights 1&2&4, dryer ntc/ fan motor
f14 lights 1&2&3, dryer heater
f15 lights 1&2&3&4, dryer heater relay
f16 N/A
f17 light 4, door lock
f18 light 3 comms error (3 phase motor) power board
f1 and f17 share the same light
F13.
– Check efficiency of contacts on connector J011 (commutator) or
J14 (three-phase) on PCB;
– Check NTC impedance value on wiring connectors J011
(commutator) or J14 (three-phase) between pin 1 and pin 2.
The impedance value at ambient temperature (20°C) must be
approximately 20 KOhm;
– If measurement is incorrect check NTC wiring;
– Check the same parameter directly on the NTC (20 KOhm);
– Renew NTC;
– Renew PCB.