Hotpoint WMF940P(UK)R

Viewing 7 posts - 1 through 7 (of 7 total)
  • Author
    Posts
  • #79396
    RickT
    Participant

    Hi. Need a bit of info here. Start machine, door locks, pumps for approx 1-2 seconds then nothing. Display stays lit. Door stays locked.Remove mains plug. One of the relays on the pcb clicks. I then plug machine in and the door unlocks. Have tested for earth leakages, all ok. Any info appreciated.

    #409027
    timdowning
    Participant

    Re: Hotpoint WMF940P(UK)R

    Assuming the motor / connections are ok, then I’m sure it will be one of those software faults. There is a reset of the pressure switch around here somewhere that can work. This fault normally happens after a blockage / when the filter has been cleaned.

    #409028
    RickT
    Participant

    Re: Hotpoint WMF940P(UK)R

    Thanks for the info. I did check motor/plug and was ok.
    Will pop back and try the reset though. I did notice the kick plate had been removed so I,m thinking there may have been a blocked filter before hand.

    #409029
    johnnyj
    Participant

    Re: Hotpoint WMF940P(UK)R

    You did check the brushes they can cause faults like that on arcadia machines.

    #409030
    iadom
    Moderator

    Re: Hotpoint WMF940P(UK)R

    3 phase motor. 😉

    #409031
    johnnyj
    Participant

    Re: Hotpoint WMF940P(UK)R

    iadom wrote:3 phase motor. 😉

    Oops my mistake itl be the board then

    #409032
    RickT
    Participant

    Re: Hotpoint WMF940P(UK)R

    Thanks for the inputs. Recalled this evening. Reset pressure system, no joy. Re-checked 3 phase motor, tacho (114 ohms) coil readings from the remain 3 tags were approx 3.5-3.8 ohms. EMW will be getting a call in the morning. Think it may be the transformer down. Will let you know the outcome.

Viewing 7 posts - 1 through 7 (of 7 total)