    shaun67
    Participant

    Hi does anyone know what the NTC should read on this tumble dryer ? the one on the heater .Problem is no heat only cold air, had a new pcb under warranty then heater stops heating a few months later.

    Checked element with megger and multi meter and all fine ..Stat with reset button on is fine and the NTC is reading just over 25k ohms .Heat exchanger is clear etc.

    Cheers

    Shaun

    #411975
    electrofix
    Moderator

    Re: Beko DSC85W No Heat

    one on heater 19500 ohms at 25 degrees C

    one over door 12000 ohms @ 25 degrees C

    have sent you a pm with an attached file

    have got a bit more info if that file is not enough

    Dave

    #411976
    shaun67
    Participant

    Re: Beko DSC85W No Heat

    Thanks Dave,have sent you a pm.

    Shaun

    #411977
    shaun67
    Participant

    Re: Beko DSC85W No Heat

    Update knew board cured fault.

Viewing 4 posts - 1 through 4 (of 4 total)