Beko CTD MODEL.DCU7230

Viewing 4 posts - 1 through 4 (of 4 total)
  • Author
    Posts
  • #80229
    smeghead
    Participant

    No heat on this dryer, checked element & reset button at back/ all ok.
    Not familiar with Beko, so had pcb apart to check for joints etc- looks Ok.

    Any clues anyone or shall I just quote for new PCB.

    Dont normally go out to Beko, but its a friend( well , was ’till she rung up & said she got a Beko.)

    Any help appreciated.
    Clive.

    #412165
    Seamy
    Participant

    Re: Beko CTD MODEL.DCU7230

    NTC on heater is prone to going low to earth, P.C.Bs also prone to failure, quote for heater & P.C.B to be safe

    #412166
    smeghead
    Participant

    Re: Beko CTD MODEL.DCU7230

    ok
    didn’t check ntc for earth fault to be honest, thanks for feedback , will go & double check ntc.
    cheers.

    #412167
    keithwilliams
    Participant

    Re: Beko CTD MODEL.DCU7230

    any chance of telling us what fixed this in the end please. I didn’t check ntc either but if that’s what fixed yours then I don’t need to order a pcb.
    to be honest these are only 180 quid at mo so she might not buy a pcb anyway.

    thanks

Viewing 4 posts - 1 through 4 (of 4 total)
  • You must be logged in to reply to this topic.