Beko CDA660 fridge freezer intermittent circulation fan

Home Forums Trade Technical & Spare Parts Forums Trade Technical Enquiries Beko CDA660 fridge freezer intermittent circulation fan

Viewing 7 posts - 1 through 7 (of 7 total)
  • Author
    Posts
  • #81479
    Washdisher
    Participant

    also ice on floor of freezer which I’d normally associate with a blocked drain or defective gutter heater, however the gutter was clear of ice.

    All defrost components have continuity.

    The fan seems ok with no radial play and axial play as expected.

    Control board looked ok and there were no lose connections.

    My guess is control board of fan motor. Has anyone else come across similar fault with this model?

    Thanks, Dez

    #416759
    electrofix
    Moderator

    Re: Beko CDA660 fridge freezer intermittent circulation fan

    there are 3 of these units with similar models but since you are mentioned a circuit board i would guess yours is CDA660FW

    from the picture of the board there is a capacitor ( big blue block). this will provide the power to the board. change that first and see what happens cheap fix if it works and you cant loose a lot if it does not

    from the picture looks like a 1uF

    look in trade forum in the stickies at the top for pcb fixes its well documents by me and others

    hope it helps

    Dave

    if you want the wiring diag, for what its worth, let me know but check full model no first

    #416760
    Washdisher
    Participant

    Re: Beko CDA660 fridge freezer intermittent circulation fan

    Hi Dave, I’d really appreciate wiring diag. It’s a CDA660F. I also suspected the defrost timer but I can’t find it anywhere on the appliance – I paid particular attention to the space behind, where the compressor is housed. Is it possible that on some models, the defrost timer is built into the pcb and not a separate part as shown on parts lists?

    Thanks for your help

    Dez

    #416761
    electrofix
    Moderator

    Re: Beko CDA660 fridge freezer intermittent circulation fan

    unfortunatly there are 3

    1 CDA660 FS 7511620008
    2 CDA660 FS 7511620010
    3 CDA660 FW 7511620009

    since 1 and 2 dont have electronic panel will send you diag no 3

    Dave

    #416762
    Washdisher
    Participant

    Re: Beko CDA660 fridge freezer intermittent circulation fan

    Hi Dave,

    Thanks for the diags – v helpful. I see that the compressor and fan have a common feed from the PCB and that there are (as I expected) no switches in series with the fan. Assuming the wiring diag isn’t too over simplified then this implies that the fan should always operate if the compressor is running (or trying to). Assuming no faulty connections or breaks in the cable to the fan, would you say this a correct assumption?

    Dez

    #416763
    electrofix
    Moderator

    Re: Beko CDA660 fridge freezer intermittent circulation fan

    i would say you are correct as there is no point haveing a fan running 24 hours a day it would make sense to switch it in with the compressor. you could do a continuity test to proove it

    but my money would still be on the poss board capacitor

    Dave

    #416764
    Washdisher
    Participant

    Re: Beko CDA660 fridge freezer intermittent circulation fan

    Hi Dave,

    Thanks for your help and patience – I’ll let you know the outcome.

    Dez