Home › Forums › Public Support Forums › Help And Support › Washing Machine Help Forum › Hotpoint WT721 F08 error code
- This topic has 5 replies, 2 voices, and was last updated 11 years, 6 months ago by
spannerman43.
-
AuthorPosts
-
September 27, 2014 at 11:13 am #82387
spannerman43
ParticipantHi All,
I have a Hotpoint WT721 that is displaying F08, all lights were flashing it started to wash and now flashes F08.
Help!!1 have a young family and mountain of clothes to wash, would rather repair it that just dump it and buy a new machine. I am very competent with a multimeter.
Kind regards
Andy
September 27, 2014 at 11:24 am #419692Martin
ParticipantRe: Hotpoint WT721 F08 error code
F08 : Oh dear, bad news, heater related fault. Could be a faulty heater, thermistor, duff control board, bad connection, wrong time of the month or a sudden change in wind direction. I kid you not F08 is a difficult fix and I wish you well solving it from the clues I gave. :tup:
September 27, 2014 at 11:28 am #419693spannerman43
ParticipantRe: Hotpoint WT721 F08 error code
Hi Martin,
OK thank you, so with heater could it just be O/C? Is the thermistor on the heater? like a plug in unit? Connections I can check no problem. I had heard someone say it could be worn brushes? I guess thats not true?
With control PCB are they just plug and play or do they need to be programmed?
Kind regards
AndySeptember 27, 2014 at 12:40 pm #419694Martin
ParticipantHotpoint WT721 F08 error code
spannerman43 wrote:so with heater could it just be O/C?
Could be.
spannerman43 wrote:Is the thermistor on the heater?
Yes
spannerman43 wrote:like a plug in unit?
Yes
spannerman43 wrote:I had heard someone say it could be worn brushes? I guess thats not true?
Not true
spannerman43 wrote:With control PCB are they just plug and play or do they need to be programmed?
The latter
September 29, 2014 at 5:48 pm #419695spannerman43
ParticipantRe: Hotpoint WT721 F08 error code
Ok, Can I test the thermistor? I was thinking if I use a multimeter on the two terminals and put the thermistor in cup of hot water the resistance should change? indicating it is OK? Or are they more complex or a better way to test?
September 29, 2014 at 9:34 pm #419696Martin
ParticipantRe: Hotpoint WT721 F08 error code
You are correct, the resistance across those terminals (measured in Kohms) will change as the temperature fluctuates up or down. 😀
-
AuthorPosts
- You must be logged in to reply to this topic.