    Siemens E12 46 is tripping RCD when on increasing spin speed. Can anyone offer advice please.

    #420049
    Martin
    Participant

    Re: Siemens E12 46 trips RCD on increasing spin speed

    Do please furnish us with the full model number(ENr number)…….

    #420050
    hammy595
    Participant

    Re: Siemens E12 46 trips RCD on increasing spin speed

    Hi thanks for the reply its WM 12E46SGB-22 just disconnected the earth to the motor to fault find (naughty I know) and it runs fine. Could it be carbon build up?

    #420051
    Martin
    Participant

    Re: Siemens E12 46 trips RCD on increasing spin speed

    Yes, dismantle and thoroughly clean the motor and replace the carbons.

    #420052
    hammy595
    Participant

    Re: Siemens E12 46 trips RCD on increasing spin speed

    Have now stripped and cleaned motor (very nice design can be totally stripped) and it still trips RCD and is (obviously) ok when earth disconnected, so do you think motor is u/s (short to earth), it looked all good when apart and runs fine when earth is off. I have a megger but not sure where to check motor, to avoid further damage. Thanks in anticipation

    #420053
    Martin
    Participant

    Re: Siemens E12 46 trips RCD on increasing spin speed

    hammy595 wrote:I have a megger but not sure where to check motor, to avoid further damage.

    Using a Megger would never damage a motor. Usually the commutator is the problem so isolate and check that first (com segments to ground). Likewise the stator using the same method. Any reading less than 50 megohms will trip the RCD/MCB.

    #420054
    hammy595
    Participant

    Re: Siemens E12 46 trips RCD on increasing spin speed

    Hi stripped motor have checked commutator to ground (spindle) on m ohm scale and getting .01 and on multi-meter 200k range 26.0 this is on all segments looks like it is to ground to me but why all segs?

    #420055
    Martin
    Participant

    Re: Siemens E12 46 trips RCD on increasing spin speed

    The motor is knackered then (technical trade terminology) 🙁

    #420056
    hammy595
    Participant

    Re: Siemens E12 46 trips RCD on increasing spin speed

    Thanks so much for your help, have looked on here and sent a request for new one are they re-buildable (new armature) as it looks a quality item and is easily stripped by a novice ie me!!

    #420057
    Martin
    Participant

    Re: Siemens E12 46 trips RCD on increasing spin speed

    Not available in seperate parts (except the brushes). Has to be a costly complete motor otherwise. 🙁

    #420058
    hammy595
    Participant

    Re: Siemens E12 46 trips RCD on increasing spin speed

    ok, that is the same result i found,could be worse as some are more expensive and i can fit it,thanks again for your help.