I have a Bosch washer/dryer model WFT2800GB/12. It washes fine. It even dries fine, except during the last 5 minute cool-down period when it wets the washing again.
During the normal drying cycle water is let into the condenser for 2 seconds in every 3, and the pump operates for 5 seconds in 25. During the cool down period water enters continuously and the pump continues as before. The water level seems to only just reach the bottom of the drum, but just enough for it to be picked up and carried onto the washing. Any tips as to the cause/cure would be much appreciated.