December 5, 2014 at 5:11 pm #83295
hyperwitch
ParticipantI’ve inherited a Reversair tumble, My problem is i switch it on and its fine for approx 20-25mins then bang it trips my fuse box. Now i’ve checked the fuse in plug and wiring all ok, took the back off (the covering the heater) hoovered it out (pretty dusty) checked all the wiring nothing appears to frayed or shorting out. Heater element looks ok can’t see any breaks in the wiring. So I’m now out of ideas so any help is really welcome please.
December 5, 2014 at 7:17 pm #422361iadom
ModeratorRe: Creda Reversair, Model 37642
Unless you have access to a megger or suitable multimeter and know how to use one then it is time to “get someone in”. 😉
December 5, 2014 at 7:33 pm #422362lee8
ParticipantRe: Creda Reversair, Model 37642
Or just isolate the element. If it still trips probably motor, if it runs longer it’ll be element.
December 5, 2014 at 9:19 pm #422363hyperwitch
ParticipantRe: Creda Reversair, Model 37642
Stupid question i’m pretty cute when it comes to electronics but as a tumble i’m a little clueless wots the best way to isolate the heater. I take it i pull the spade terminals of the heater element and link them without the heater in situe.
December 6, 2014 at 9:04 am #422364Andy jones
ParticipantRe: Creda Reversair, Model 37642
No no. Don’t link anything together or boooom. Get someone in to look at it
December 6, 2014 at 10:07 pm #422365hyperwitch
ParticipantRe: Creda Reversair, Model 37642
Right had my brother in law take a look at it, the bottom line is the machine seems to trip when the timer hit a certain point. Just to check we isolated the door switch, same thing. Checked all the continuity that came back all fine. So we think it is the timer/programme dial, the only problem we’ve got is we can’t seem to get the bl**dy thing out any suggestions or is it not worth finding one.
December 6, 2014 at 10:41 pm #422366iadom
ModeratorRe: Creda Reversair, Model 37642
You don’t check continuity when trying to find an earth or short circuit fault. ❓
My suggestion is the same as before, get someone who knows what they are doing to look at it.
December 6, 2014 at 10:49 pm #422367hyperwitch
ParticipantRe: Creda Reversair, Model 37642
Forgot to mention that my brother in law is an electrical engineer. When i mean continuity everything read normal voltage until it tripped when the switch was turned then just before the dial got to the trip point the voltage spiked big time.
-