Home › Forums › Trade Technical & Spare Parts Forums › Trade Technical Enquiries › Interlock basics
- This topic has 11 replies, 4 voices, and was last updated 11 years, 3 months ago by
Devlin Maguire.
-
AuthorPosts
-
December 24, 2014 at 2:45 pm #83514
Devlin Maguire
ParticipantA failed inter lock everything else is ok, lid off and released the lock manually, fitted new inter and machine dead, refit old one and everything ok except of course door wont open , so faulty new inter ?? supplier says no whats the opinion guys and gals
DevDecember 24, 2014 at 3:08 pm #422936iadom
ModeratorRe: Interlock basics
FORUM BASICS, make and model??????? 😀
December 24, 2014 at 4:43 pm #422937Devlin Maguire
ParticipantRe: Interlock basics
Sorry
Hotpoint WDM73A,December 24, 2014 at 5:22 pm #422938iadom
ModeratorRe: Interlock basics
Fitted hundreds of those interlocks, never had a new one faulty, genuine or pattern.
Would suggest very close examination of both control and power module triacs and also look for any other visible signs of damage on pcb’s.
If one of these interlocks has jammed then it is virtually impossible to open them again without physically breaking them. The door will stay locked if machine is full of water or pressure switch has failed but pressure switch failure is not common.
If the door lock has shorted out then it is 99.9{e5d1b7155a01ef1f3b9c9968eaba33524ee81600d00d4be2b4d93ac2e58cec2d} certain that it has damaged one or both of the pcb’s. 🙁
December 24, 2014 at 5:38 pm #422939madangler1
ParticipantRe: Interlock basics
What’s the part number of the lock ? It’s either the instant lock ending in 755 or the std one . It’s very odd for a door lock to kill all power on a HP. The motor and pump is wired through it but not mains in. Also check your putting the plug in the correct way some have to be reversed to work. The new versions also can have different PIN numbers. The old lock has 3,4,5 and the new one has 2,3,4. On these you wire it 2-3 3-4 and 4-5.
December 24, 2014 at 6:12 pm #422940iadom
ModeratorRe: Interlock basics
This one doesn’t have the plug, it’s the old style 1602390 interlock. similar model to a WD72, in fact like all WM/WD machines.
December 25, 2014 at 9:54 am #422941Devlin Maguire
ParticipantRe: Interlock basics
I dont think its the boards as it runs through a program till the end with the original door interlock fitted it simply wont release the door, the “new” inter fitted the machine is dead with supply going all the way down to the inter, does any one now what I should read in resistance through the interlock I have a Brown via the on/off switch Black and Red, Brown and Black supply the “lock” so what should the ohms be at this point. I therefore assume that the red becomes main supply to the boards, thanks for your patience chaps
DevDecember 26, 2014 at 2:06 pm #422942simonb
ParticipantRe: Interlock basics
the old locks on wm range may have welded contacts but no neutral supply going from the lock to the board, unscrew and sling back timer check for shorted tracks, most simple repair of resoldering and replace the lock, check door seal for holes.
December 26, 2014 at 7:03 pm #422943Devlin Maguire
ParticipantRe: Interlock basics
Cheers Simon may try that on Sat morn
DevDecember 27, 2014 at 9:49 am #422944iadom
ModeratorRe: Interlock basics
No timer on this one Simon, it was the very last production run of the Ultima range, basically a WD72.
I still think some pcb damage has occurred.
I can you the WD72 manual if you like Devlin.
Jim.
December 28, 2014 at 7:17 pm #422945Devlin Maguire
ParticipantRe: Interlock basics
Cheers jim the manual would be a big help
DevDecember 28, 2014 at 8:11 pm #422946iadom
ModeratorRe: Interlock basics
PM me your e mail address. 😉
-