Model AWZ612
Called recently to a no heat on drying cycle
Found resettable TOC open circuit
Reset. Unit producing heat
Removed heat chamber cover to check for blockage..clean
Checked air inlet to drum. Again clear
Air fan running
Ran dryer cycle all ok.
Client rang today again no heat on dryer
Asked her about load size..says just a normal basket full?
Any ideas where to check out next
Thermostats etc
Or has resettable TOC failed
Many thanks
Graham