Hoover DYN9144 D3X error E03 & E16

Home Forums Trade Technical & Spare Parts Forums Trade Technical Enquiries Hoover DYN9144 D3X error E03 & E16

Viewing 6 posts - 1 through 6 (of 6 total)
  • Author
    Posts
  • #87626
    smeghead
    Participant

    Had a look at this today, it’s only 20 months old with light usage.
    E16/ heating, all ok
    E03/ pump, filter & no blockages.
    Told her to do a high temp wash in case of sludge in pressure chamber(in tank).
    She’s just text to say stopped half way through with E03.
    Any clues anyone ??
    Or shall I stick a pump on it ?
    Cheers all
    Clive.

    #435460
    timdowning
    Participant

    Re: Hoover DYN9144 D3X error E03 & E16

    Change the heater, make sure it’s genuine one with ntc.

    #435461
    smeghead
    Participant

    Re: Hoover DYN9144 D3X error E03 & E16

    Hi Tim
    I did check heater for earth fault & resistance , seemed OK.
    Are they suspect under load?

    #435462
    Hollytree_Technical
    Participant

    Re: Hoover DYN9144 D3X error E03 & E16

    Yes – get it hot and then test the insulation and you will find that his dropped.

    Jem

    #435463
    smeghead
    Participant

    Re: Hoover DYN9144 D3X error E03 & E16

    Ok,cheers all, going tomorrow, so will try that.
    Thanks again.

    #435464
    Andy jones
    Participant

    Re: Hoover DYN9144 D3X error E03 & E16

    Yep almost certainly the heater. Had this problem a few times

Viewing 6 posts - 1 through 6 (of 6 total)