Home › Forums › Public Support Forums › Help And Support › Fridge And Freezer Forum › beko American fridge freezer fault
- This topic has 7 replies, 3 voices, and was last updated 8 years, 11 months ago by
EnglisHero.
-
AuthorPosts
-
April 14, 2017 at 9:42 pm #91047
EnglisHero
ParticipantI have a Beko GNEV320APS that has decided to stop freezing and chilling.
after a few checks I have found that the compressor overload has been dropping out.
proved the condenser coils were reading correct ohms and it took me a few hours scratching my head while trying work out why, before noticing that the condensing fan was not running. so have tested it and it does not work, tries to spin but just aint got the umpth.
if I replace the fan would this be sufficient to keep the condenser overload from tripping or would I be throwing money at a duff fridge freezer.
I can hear the condenser run up then sounds likes its trying to hard before tripping.any help would be good.
April 14, 2017 at 11:26 pm #446851electrofix
ModeratorRe: beko American fridge freezer fault
you say condenser but do you mean compressor
ie does it trip out straight away or does it take 10 mins or so
Dave
April 15, 2017 at 7:23 am #446852EnglisHero
ParticipantRe: beko American fridge freezer fault
Hi yes I mean compressor,
After power is switched on, it Thames about 30s for the compressor to start, after about another 30s if run time the overload trips, and when cooled it starts the compressor again and trips again, obviously the fan is no running so it’s not able to be Cooled.April 15, 2017 at 7:28 am #446853EnglisHero
ParticipantRe: beko American fridge freezer fault
I’m not able to do a load test on the unit as my meter only goes to 400ma.
The windings are 18. 2 between start & run
About 8 Com and start & similar on Com and run windingsApril 15, 2017 at 7:56 am #446854electrofix
ModeratorRe: beko American fridge freezer fault
its got all the hallmarks of a compressor failure. the compressor is taking too much current so the safety trip activates
the fan wont affect this, it will only affect its ability to cool but the compressor would still run
Dave
April 15, 2017 at 9:12 am #446855EnglisHero
ParticipantRe: beko American fridge freezer fault
Cheers Dave.
looks like a trip to the skip then.
I guess if you buy a £700 fridge freezer, don’t expect it to last 4 years plus.April 16, 2017 at 6:06 am #446856Simon46
ParticipantRe: beko American fridge freezer fault
Is the compresser cold when it trips after 30 secs? Was going to suggest a desk fan pointed at it to try.
April 16, 2017 at 7:42 am #446857EnglisHero
ParticipantRe: beko American fridge freezer fault
As the faulty fan had failed I thought it cooled the evaporation rad that kept the compressor cool preventing the overload, but have no desk fan, have moved it to outside now so after a good old rainy day it won’t be much good anyway.
-