    Participant

    hi guys just been to this e11 fault was hoping to see the drier wires broken seem fine ,, the sensor state …am getting a ready only on the highest ohms scale 2000k of about 100 . is that normal ? if is ? what else could it be ? pcb ❓

    #450474
    adv
    Participant

    Re: hoover wdryer wdyn458a

    reading mean sorry

    #450475
    kaibart
    Moderator

    Re: hoover wdryer wdyn458a

    E11 fault open circuit heater ntc probe and or module that’s what the error code means

    #450476
    adv
    Participant

    Re: hoover wdryer wdyn458a

    yeh but what does the probes resistance read if ok

    #450477
    adv
    Participant

    Re: hoover wdryer wdyn458a

    so your saying the probe is only faulty if open circuit then ?

    #450478
    kaibart
    Moderator

    Re: hoover wdryer wdyn458a

    I’ve put exactly what’s on Hoover’s service error code list my sure ntc should read about 28kohms. Only faults I’ve had on these are blocked condenser and the fan motor coming loose on upper housing.

    #450479
    adv
    Participant

    Re: hoover wdryer wdyn458a

    ok cheers ..looked on connect. model doesnt even register. qualtex here ..sensor not listed even on hoover site mmmm strange..aaahhh through too feck then

    #450480
    kaibart
    Moderator

    Re: hoover wdryer wdyn458a

    It’s the wrong model number thats why 3 listed wdyn854dg-86s wdyn854db-80 wdyn854d-80 sensor should be the same on all 3 models will pm you some info kai