    Creda, Hotpoint, Proline and Indesit Dryer Stat Kits.

    From 1991 onwards, the above dryers used thermostat sets comprising a control stat and a one time safety stat. When these fail, they must be replaced as a pair in the form of a kit. This article will outline the various kits and how to identify the one you may need.

    1741124 – Control stat – 85c – contacts raised, positioned 9 + 3 o’clock
    – Safety stat – 109c – contacts raised, positioned 12 + 6 o’clock

    1701896 – Control stat – 106c – contacts flat, positioned 9 + 3 o’clock
    – Safety stat – 150c – Blue spot – contacts flat, positioned 10 + 4 o’clock

    1701583 – Control stat -106c – contacts flat, positioned 9 + 3 o’clock
    – Safety stat – 130c – Green spot – contacts flat, positioned 9 + 3 o’clock

    1701557 – Control stat – 113c – contacts flat, positioned 9 + 3 o’clock
    – Safety stat – 120c – Red spot – contacts flat, positioned 9 + 3 o’clock

    1701774 – Control stat – 85c – Purple spot – contacts flat, positioned 9 + 3 o’clock
    – Safety stat – 120c – Red spot – contacts flat, positioned 9 + 3 o’clock

    1702041 – Control stat – 85c – Purple spot – contacts flat, positioned 9 + 3 o’clock,
    – Safety stat – 109c – White spot (where visible) – contacts flat, positioned
    9 + 3 o’clock

    Where the stats are ceramic (white), temperature ratings are printed on the body.

    All these kits may be found in Shop at UKWhitegoods.co.uk


    REMEMBER – All investigations to be carried out with the power OFF.