  • #92470
    prs999
    Participant

    Hi All,

    My oven has been tripping the main RCD when it gets hot, on average about 125 degrees, I have had it apart and as first suggested I changed the element to no avail.

    I have since had it out completely and had the back off, it seems that the Fan is the cause, If I disconnect it the RCD holds and as soon as I touch either of the cables on their terminals it trips.

    when I do an insulation resistance test I get the following results

    Cold 1Mohm
    Hot 0Mohm

    My main question is 1Mohm to me is not high enough for a cold fan?
    Also Any ideas, I have stripped down the fan and I can’t see anything wrong or even the slightly bit damaged.

    Thanks

    #451373
    kwatt
    Keymaster

    Re: Smeg Oven Fan Motor

    Can you give the model number please?

    K.

    #451374
    prs999
    Participant

    Re: Smeg Oven Fan Motor

    SUK61MFX

    #451375
    kwatt
    Keymaster

    Re: Smeg Oven Fan Motor

    Cooling fan motor makes sense or the fan initiation stat.

    If it’s a plastic cased one, Smeg says it’s obsolete now.

    If it’s metal then it’s this one:

    https://shop.ukwhitegoods.co.uk/6952105 … -fan-motor

    And it is noted that they are not interchangeable.

    But do keep in mind that there may be other causes.

    K.

    #451376
    prs999
    Participant

    Re: Smeg Oven Fan Motor

    Hi Apologies,

    It is the internal oven fan with the element around it

    I am assuming that as this is always on when the oven is in fan mode that there is no stat on this fan?

    #451377
    kwatt
    Keymaster

    Re: Smeg Oven Fan Motor

    The main oven fan should kick on as soon as the oven is energised and, if they’re gonna go like that it’ll usually pop the trip straight out the gate.

    It’s possible of course that it’s gone that way but, it’s pretty unusual.

    But at 125?C or thereabouts, the cooling fan will (or should) kick in on the cooling fan control or initiation stat and if it bangs out when it hits that sort of temp I’d have thought those to be more likely suspects.

    K.

    #451378
    prs999
    Participant

    Re: Smeg Oven Fan Motor

    Great thanks for your reply, I will investigate more.

    If I turn the oven off at the control panel the RCD holds but the cooling fan still overruns for a bit as it should but does not trip the RCD, it only goes again if I try to put the oven into any of the fan assisted modes

    Thanks