Are both sets of contacts on this machines, stats ‘NO’.
It overheats on Prog 9 (40 degree wash) but works fine on Prog 3 (60 wash)
If I turn the timer to prog 4 (40 wash) after it has overheated it advances normally.
When the water temp is high, both sets of stat contacts are closed. When I cool them down, the outer contacts are ‘OC’ but the centre ones remain closed.
Suspect control unit, any better ideas?
That would suggest the 40/60 temps are achieved with timed heat which suggests my suspicions about the control unit could well be correct, unless there is another stat at the front of the drum?