    AdamPB
    Participant

    Hi all. Hoping someone can help.

    I picked up a second hand Liebherr wine cooler (Wtes 1753) on Sunday and temp seems to be fluctuating rapidly.

    When first moving it onto the dolly it leaked a little. I transported it on its back (my only option) but tilted. And when home, I let it sit for 3hours before turning on.

    With no bottles inside I’ve been running for 24hrs and it moves from 12c to 7c within 20mins and the humidity from 16{e5d1b7155a01ef1f3b9c9968eaba33524ee81600d00d4be2b4d93ac2e58cec2d} to 40{e5d1b7155a01ef1f3b9c9968eaba33524ee81600d00d4be2b4d93ac2e58cec2d} in the same time. All readings are from a digital temp/humidity gauge with new batteries.

    The coolers temp display shows no fluctuation and stays at 14c (the desired temp I set)

    https://www.avforums.com/attachments…-jpeg.1150689/

    Anyone have any ideas? Thanks in advance!

    #461575
    Tony R
    Participant

    Hi Adam, can you supply the index number and service number.

    #461576
    AdamPB
    Participant

    Thanks for the reply.

    Index No: 20 / 001
    Service No: 9983125-00

    model: wtes 1753

    #461577
    AdamPB
    Participant

    Hi Tony. As a further update I’ve turned the unit off and vacuumed the air intake in the plinth as per the instructions in the manual. Not sure if this will help.

    Thanks.

    #461578
    Tony R
    Participant

    Caused by the construction form and the different operating conditions, a certain divergence between air temperature in the compartment and the displayed temperature cannot be avoided.
    However a new integral power board was produced for this model up to index 21C, but I cannot find it as a spare available now, your unit was produced in 2005.

    #461579
    AdamPB
    Participant

    Thanks tony. Are you saying it’s failing because it’s multi temp? (when you state “different conditions” and “construction form”) just struggling to understand the diagnosis in simple terms 🙂

    So if the power board has failed and there’s no spares in production anymore, would a newer PB be compatible? If not, any other options?

    Thanks