    Taff543489
    Participant

    Can anyone confirm that E3 on this machine is an drain fault? The machine empties and fills correctly. The pressure switch has been replaced and the pressure chamber and hose is clear. I suspect the control module? Anyone had the same problem before I order a new control module? Regards Taff

    #465807
    murv
    Participant

    If it drains okay & pressure system is not blocked then it’s commonly the result of intermittent earth fault on the wash element. It should show E16 but the diagnostic software often gets it wrong and comes up with E3 towards the end of program.

    Murv…

    #465808
    darren14770
    Participant

    Usually happen just before the final rinse shows as a e3 but it you turn selector dial to off and turn back on quickly to a different programme will show as an e16 . Testing element for continuity or earth leakage won’t show as a fault , but resistance is either to high or to low so it triggers a fault code . Change heating element and all will be good . Not sure what accepted ohms readings PCB is programmed to accept as normal