Beko tumble dryer not heating up

Home Forums Public Support Forums Help And Support Tumble Dryer Help Forum Beko tumble dryer not heating up

Viewing 10 posts - 1 through 10 (of 10 total)
  • Author
    Posts
  • #99235
    Paigntontim
    Participant

    Hi all,

    i have a beko dhr73431w heat pump tumble dryer. This morning I turned on as normal and found this is not heating up.

    i put this into test mode and come up with error codes

    01 & 02

    i have tested the water pump & the overflow switch all good ,
    Also, can not hear the compressor kicking in

    I’m stumped any advice would be great

    Also when I opened the sides there was no capicitors but starts fine, I was lead to believe there should be 2?? 1 for starting and the other for the heat pump?

    thanks

    tim

    #475564
    electrofix
    Moderator

    error 1 is a door open fault

    error 2 is overflow sw error

    if you have looked at overflow sw there is no reason you should be getting E02

    Dave

    #475565
    Paigntontim
    Participant

    Thanks dave for your reply

    tested the overflow sw on a multimeter and all seems fine. In your option replace the switch?

    thanks

    #475566
    electrofix
    Moderator

    not without more checking

    i assume the board thinks its full or the like

    do a resistance test across it both closed and see if you get any reading when its open on a high scale

    Dave

    #475567
    Paigntontim
    Participant

    The panel is normall , no warning lights on,just checked the switch closed is no continuity open .3,

    thanks Dave for all your help so far

    #475568
    electrofix
    Moderator

    could the test mode be coming up with historic codes so no longer relavent


    Dave

    #475569
    Paigntontim
    Participant

    This is what I thought

    any ideas how to clear these codes?

    thanks tim

    #475570
    electrofix
    Moderator

    no on test mode the unit displays the last 5 fault codes so its likley your codes are historic

    also in the test proceedure you will not get past stage 10 without short circuiting the sensor plate within 10 secs. The compressor test is on stage 13

    Dave

    #475571
    Paigntontim
    Participant

    Just went into the test mode and stopped at number 6

    nt 01
    nt02 error codes now, any ideas how to fix this one? Or is this the same ones as before?
    thanks tim

    #475572
    electrofix
    Moderator

    they are not error codes

    NTC is a thermistor the display should be showing values of Nt1 and Nt2

    manual states
    If NTC and Voltage Error occurs, Err:or appears on the display and the service test cannot
    be passed to the next steps

    Dave

Viewing 10 posts - 1 through 10 (of 10 total)