Neff small integrated fridge stopped cooling –

Home Forums Public Support Forums Help And Support Fridge And Freezer Forum Neff small integrated fridge stopped cooling –

Viewing 5 posts - 1 through 5 (of 5 total)
  • Author
    Posts
  • #99778
    rbfrics7
    Participant

    Neff K4316X4GB/04 – stopped cooling – replaced relay – no better – when fridge is turned on compressor runs for about 10 sections then stops – after say another 10 sections you can hear the system trying to start but it doesnt – the readings across the compressor pins are approx. 35, 21and 16 ohms – any ideas as to whats wrong and what to do – the fridge is about 10 yrs old – Many thanks

    #477862
    electrofix
    Moderator

    does sound like compressor failure

    Dave

    #477863
    rbfrics7
    Participant

    Thanks for that Dave – is that based upon the readings that I obtained across the compressor pins?
    Do you know what sort of reading should be obtained?
    Thank you

    #477864
    electrofix
    Moderator

    no its based on the fact you replaced the overload but the compressor still tripped it

    so compressor is being powered but cant start. there are only 2 reasons for that . Motor capacitor, if your unit uses one, or compressor failure

    Dave

    #477865
    rbfrics7
    Participant

    Thanks for your advice Dave