BOSCH WTV74307UK stops after a few minutes

Home Forums Trade Technical & Spare Parts Forums Trade Technical Enquiries BOSCH WTV74307UK stops after a few minutes

Viewing 6 posts - 1 through 6 (of 6 total)
  • Author
    Posts
  • #99860
    delta01
    Participant

    hi any clues please, i had this on the condenser version and it was a thermistor at the bottom front but there isn’t one one this version thanks john

    #478202
    electrofix
    Moderator

    does it still stop on timed programmes ?

    Dave

    #478203
    delta01
    Participant

    i will check it thanks

    #478204
    delta01
    Participant

    hi Dave yes it does,and all vent areas clear the heater and stats all measured ok

    #478205
    electrofix
    Moderator

    if it has not front thermistor I can only assume its detecting moisture through the drum or metal strips. make sure these strips are not contaminated, short circuit and are connected to the timer. pull the connecters off the timer and put them back in case of bad joints
    assume you are trying with wet washing in

    Dave

    #478206
    delta01
    Participant

    thanks Dave will try

Viewing 6 posts - 1 through 6 (of 6 total)