Siemens hb73ab541s oven – Trips fuse

Home Forums Public Support Forums Help And Support Cooker And Oven Forum Siemens hb73ab541s oven – Trips fuse

Viewing 15 posts - 1 through 15 (of 25 total)
  • Author
    Posts
  • #96920
    Gardenviking
    Participant

    Hi,
    My Siemens oven trips the fuse when I use the selector switch. At «0» fuse is ok. Every other function trips the fuse, also the «light only» Anyone having at tip for faultfinding?

    #465376
    Specialist01269
    Participant

    Is it the MCB (Fuse) that trips out or the RCD (Main breaker) ?.

    #465377
    Gardenviking
    Participant

    Unfortunately its hard to say. It is a common fuse for both short circuit and earth fault.

    EDIT: Have checked the manual for the fuse, and can confirm it is earth fault.

    #465378
    Gardenviking
    Participant

    I have also disconnected the upper and lower element and secured the cables. Fault still present, and tripping when activating the selector. I think maybe one of the circuit boards causes the problem?

    #465379
    Specialist01269
    Participant

    Are you sure that the RCBO manual indicates an Earth fault ?.

    #465380
    electrofix
    Moderator

    if its an rcd that’s tripping it will be the one with the test button on it

    most likely problem is an element failure and there seems to be 3 of them

    Dave

    #465381
    Specialist01269
    Participant

    From the description it’s an RCBO rather than an RCD. So it serves both functions: Overcurrent and Earth leakage protection, agreed it’s much more likely to be an element at fault.

    #465382
    Gardenviking
    Participant

    Thanks, I will try to disconnect all of them at the same time. But shouldnt the fuse trip only when elements are activated? Or is there any self diagnostic in the electronics? I live in Norway, so I am not sure of the difference and the function of the RCBO or RCD. What do the letters mean? Anyway, I have a automatic fuse, releasing for shortcircuit, overload and earthfault. According to the supplier, a white spot on the lower part of the fuse will turn blue when released for earthfault. So i am quite sure it is earth fault causing my problems.

    #465383
    Specialist01269
    Participant

    Hi: As above an RCD detects earth fault current, An RCBO will detect earth fault current and also Overcurrent in the Live / Neutral circuit.
    From your original description it appeared that the circuit breaker did trip when the elements were activated as you said everything was ok until you turned the selector switch on.

    #465384
    Gardenviking
    Participant

    Hm, I am sorry for my bad problem description. The selector switch has a postition for only light. The fuse trips at once, when moving the selector from «0» (top) At «0» there is only power to the clock and display.

    #465385
    electrofix
    Moderator

    you said you disconnected 2 elements so I would suspect the one you have not disconnected is the fault

    you also said you disconnected upper and lower elements so its likely the fan element is at fault which is the only one still connected

    Dave

    #465386
    Gardenviking
    Participant

    Thanks! I did not know there was three of them…. Probably the blue and orange wire going down in the top at right? The orange direct from the selector. Disconnected the orange, and no fuse trip. But unfortunately no other functions. Maybe try to dismantle the element and heat dry it for some hours? And order new one?It would be great if I could get the oven up and running for christmas…

    #465387
    electrofix
    Moderator

    unless its got damp I would doubt heating it would help
    But
    although I have not got the complete Enr number the model I looked up looks like you have 2 oven settings
    fan oven which uses a circular element round the fan ( which I think is faulty)

    convection oven which uses the top and bottom elements. There may also be a fan convection position but you would have to check that

    its highly likely if you disconnect the fan element and make sure the wires are insulated and cant touch anything that the convection oven will work

    Dave

    #465388
    Gardenviking
    Participant

    Hello again. Not so lucky. Disconnected all THREE elements, fault still present. Also disconnected the upper and lower fan, same same.

    #465389
    electrofix
    Moderator

    did you disconnect both wire from the elements and fans ?

    you should have 4 wires disconnected from red arrow
    2 wires disconnected from yellow
    and 2 wires from blue

    Dave

Viewing 15 posts - 1 through 15 (of 25 total)